A phase change material (PCM) thermal battery stores heat in a material that melts as it absorbs heat and freezes as it gives it back. Most of the energy goes into the change of state, so the unit holds a lot of heat within a narrow temperature band and releases it at a steady temperature. It stores heat, not electricity.
Plants make heat at one time and need it at another. A boiler stack runs all day. A wash cycle, a dryer or a turbine may want that heat only in bursts. Without storage, the extra heat goes up the stack or out a cooling tower. A thermal battery closes that gap.
Sensible heat and latent heat
There are two ways to store heat in a material.
Sensible storage: the material gets hotter
A hot water tank is the familiar example. Add heat and the water warms up. Take heat out and it cools down. The energy stored depends on how much the temperature changes. That is simple and cheap, but the tank's output temperature drifts as it empties.
Latent storage: the material changes state
A phase change material works differently. As it reaches its melting point, it keeps absorbing heat while it melts, with little change in temperature. When the heat is needed, the material freezes and gives that energy back. Researchers describe latent heat storage as relying on the phase change enthalpy of the material to store heat within a narrow temperature range, and PCMs are typically more energy dense than purely sensible materials.
That gives a thermal battery two useful traits: compact storage and a steady delivery temperature. We do not quote a general multiple for how much more it stores, because the gain depends on the material and the temperature swing you compare against.
How a PCM thermal battery works
The cycle has four steps.
- Capture. Heat comes from a source such as exhaust, hot water, steam or thermal oil.
- Charge. A heat-transfer fluid carries the heat through tubing embedded in the PCM. The material melts and banks the energy.
- Hold. The heat stays in the unit until it is called for.
- Discharge. The material freezes and releases the heat, to a process loop or to an ORC turbine for power.
Nothing is consumed. The material melts and freezes again, cycle after cycle.

Where it helps a plant
- Smoothing a mismatch. Heat is recovered steadily but used in peaks. The battery absorbs the gap.
- Feeding a power cycle. An ORC turbine runs best on a steady heat input. A battery can turn an uneven source into a steady one. Read more in can waste heat be converted into electricity.
- Holding recovered heat. Heat captured from flue gas by a condensing heat recovery unit is only worth something if it is used. Storage lets it wait for the load.
- Shifting when heat is used. The U.S. Department of Energy notes that thermal energy storage can hold heat for use at a different time, from hours to weeks, and that more than 45 percent of electricity use in U.S. buildings goes to thermal needs such as air conditioning and water heating.
What a PCM battery has to get right
PCM storage is not magic. Researchers at the U.S. national laboratories point to a hard design trade: a good PCM needs high energy density and good heat transport together, and both are hard to predict from simple models. Four practical limits follow.
- Match the temperature. The melting point must sit between the heat source temperature and the temperature the load needs. A mismatch wastes the whole idea.
- Heat moves slowly. Many PCMs conduct heat poorly, so how fast a unit can charge and discharge depends on its internal heat-exchange design, not just on how much material it holds.
- Supercooling and cycling. Some materials stay liquid below their freezing point, and some degrade over many cycles. Testing has to separate reversible effects from true degradation.
- Volume change. Materials expand and shrink as they melt and freeze, and the unit has to allow for it.
How Novacab TESS fits
Novacab TESS is a rechargeable thermal battery built on a synthetic phase change material programmed for a chosen temperature band. The platform can be configured to harvest useful heat from roughly 122°F (50°C) to above 800°F (427°C), depending on the storage material, heat-transfer fluid and the equipment around it. Each unit stores and releases heat on its own. ORC modules are an add-on for sites that want power.
In a Sidel CREN system, TESS is the storage stage between recovery and use. The RPC and the SRU recover heat. TESS holds it. The process or the turbine draws it when needed. The same chain is described for several industries, including dairy and sugar mills.
How much heat a battery can bank and how well it performs are engineered targets, not guarantees. They are confirmed only by a metered baseline and a pilot at your site. Sidel CREN starts with a data request. See how we work.
Questions to ask before you consider one
- What temperature is the heat source, and how steady is it?
- What temperature does the load need, and when does it need it?
- How many hours a day does the gap between supply and demand last?
- How fast must the unit charge and discharge?
- Is there room, and a heat-transfer loop, on site?
If you can answer those, you can tell a vendor what to size. If you cannot, the first step is metering, not equipment.
Quick answers
What is a phase change material thermal battery?
It is a storage unit that holds heat in a material that melts as it absorbs heat and freezes as it gives heat back. Because most of the energy goes into the melting itself, the unit stores a lot of heat within a narrow temperature band and releases it at a steady temperature.
How is a phase change thermal battery different from a hot water tank?
A hot water tank stores heat only by getting hotter, so its output temperature falls as it discharges. A phase change unit stores most of its heat while the material changes state, so it can deliver heat near one steady temperature and, depending on the material, hold more energy in the same space.
What are the limits of phase change heat storage?
The material has to be matched to the temperature of the heat source and the load. Many phase change materials conduct heat slowly, which limits how fast a unit can charge and discharge, and some can supercool or degrade over repeated cycles. A metered baseline and pilot confirm what a given site can expect.
- U.S. DOE Building Technologies Office: Thermal Energy Storage
- Lilley et al., Phase change materials for thermal energy storage: a perspective on linking phonon physics to performance (OSTI, 2021)
- Oak Ridge National Laboratory: Thermal property characterization of phase change materials, a systematic review (2026)